information

product

facade ceramic

Delta Elements FACADE CERAMIC is made of dry pressed, double fired porcelain stoneware. The product is solid-colored, rectified and optionally with adhesive coating on the reverse side.
It is available in plain grey or brown shades and in various natural stone looks.

Areas of application

– As wall and ceiling cladding interior/exterior
– As cladding on exterior wall insulation systems (EWI systems)
– As cladding on suspended, rear-ventilated plaster support systems

Classification according to EN 14411 ISO 13006 Annex G Group BIa with E ≤ 0.5% UGL, fire protection class A1 (with adhesive coating B1)

* The maximum permissible area sizes or edge lengths in accordance with the specifications in the General Building Inspectorate Approvals (ABZ) of the facade system manufacturers must be observed.

VALS

RESOLUT

SLATE

TRAVER

NIWALA

PLAIN

Standard Format

30 x 60 cm

Special Formats

10 x 60 cm
15 x 60 cm
20 x 60 cm
and others on request

Material Thickness

8,5 mm
9,0 mm
9,5 mm

Surfaces

series depending
smooth
rough
structured

HAVE YOU BECOME CURIOUS?

Our project managers will be happy to advise you.

PRODUCT FEATURES

FACADE SYSTEMS

Delta Elements FACADE CERAMIC may be applied on different substrates. Here you can find constructional information and documents for the application of FACADE CERAMIC on EWI systems. We would be pleased to work with you on solutions for project-specific construction- and details-solutions.

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
Joint mortar, slurry method (except Vals struc)
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
Joint mortar, slurry method (except Vals struc)
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

PROCESSING| STORAGE

The thin-bed method is used as a combined method (buttering-floating). Grouted by using the slurry method (except Vals stuc); the standard joint width is 8 mm, for large formats 10 mm. The optimum processing temperature is between 5 and 30° C. The product has to be stored implicit dry, in the shade, dust- and frost-proof.

The detailed processing instructions can be found here:

To ensure the quality of execution we offer support on construction site in cooperation with our system partners.
Therefore we can provide you with advice for a successful completion of your work.

LET YOURSELF BE INSPIRED

Vals

The surfaces and colors of the series are based on the look of the natural stone gneiss used at the Spa in Vals/Swiss Grisons. The product is available in two surface structures: the surface ‘rough’ is rough and matt and has a slight mica effect; the surface ‘struc’ is similar to this texture but much more structured.

Vals Rough

Vals Struc

Resolut

The series is defined by a characteristically vivid color scheme with a slight metal reflection. The surface structure is uneven, rough and matt; it has a fossil natural stone character. The series is available in two colors: the color ‘sand’ is beige-light brown; the color ‘grey’ is dark grey-dark brown.

Resolut Sand

Resolut Grey

SLATE

The series is test on a metamorphose, tectonic distorted segment rock. The surface shows an iridescent coloring, which uncovers the flowing lines of the splitted stone. The surface is matt and rough. The series is available in four colors: The color “sand” is beige, the color “brown” is brown, the color “grey” is grey and the color “darkgrey” is based on the dark grey color of the original stone.

SAND

GREY

BROWN

DARKGREY

TRAVER

Due to its warm coloration and its natural shade this series was inspired by travertine stone. This effect is highlighted by an exchange of a dull-rough right up to micro-involvements jagged surface. The series is available in two colors. The color “light” has a light and the color “natural” a dark effect and is based on the original stone.

LIGHT

NATURAL

NIWALA

Due to its uniformly coloration and the fine-grained involvements this series was inspired by sandstone. Against the light the surface shows an exciting switch between dull and shiny plains. The series is available in three earthy colors. “Light” is ivory, the colors “grey” and “darkgrey” have a light grey and mid grey coloring.

LIGHT

GREY

Darkgrey