information

product

facade ceramic

Delta Elements FACADE CERAMIC is made of dry pressed, double fired porcelain stoneware. The product is solid-colored, rectified and optionally with adhesive coating on the reverse side.
It is available in plain grey or brown shades and in various natural stone looks.

Areas of application

– As wall and ceiling cladding interior/exterior
– As cladding on exterior wall insulation systems (EWI systems)
– As cladding on suspended, rear-ventilated plaster support systems

Classification according to EN 14411 ISO 13006 Annex G Group BIa with E ≤ 0.5% UGL, fire protection class A1 (with adhesive coating B1)

* The maximum permissible area sizes or edge lengths in accordance with the specifications in the General Building Inspectorate Approvals (ABZ) of the facade system manufacturers must be observed.

VALS

RESOLUT

FULDA

GRACE

PLAIN

Standard Format

30 x 60 cm

Special Formats

10 x 60 cm
15 x 60 cm
20 x 60 cm
30 x 30 cm
and others on request

Material Thickness

9,5 mm

Surfaces

series depending
smooth
rough
structured

HAVE YOU BECOME CURIOUS?

Our project managers will be happy to advise you.

PRODUCT FEATURES

FACADE SYSTEMS

Delta Elements FACADE CERAMIC may be applied on different substrates. Here you can find constructional information and documents for the application of FACADE CERAMIC on EWI systems. We would be pleased to work with you on solutions for project-specific construction- and details-solutions.

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
Joint mortar, slurry method (except Vals struc)
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

  • EWI SYSTEM
  • VENTILATED
  • MASSIVE
  • DOWNLOADS

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
System-joint mortar, slurry method (except Vals struc)
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements FACADE CERAMIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements FACADE CERAMIC
Joint mortar, slurry method (except Vals struc)
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

PROCESSING| STORAGE

The thin-bed method is used as a combined method (buttering-floating). Grouted by using the slurry method (except Vals stuc); the standard joint width is 8 mm, for large formats 10 mm. The optimum processing temperature is between 5 and 30° C. The product has to be stored implicit dry, in the shade, dust- and frost-proof.

The detailed processing instructions can be found here:

To ensure the quality of execution we offer support on construction site in cooperation with our system partners.
Therefore we can provide you with advice for a successful completion of your work.

LET YOURSELF BE INSPIRED

Vals

The surfaces and colours of the series are based on the look of the natural stone gneiss used at the Spa in Vals/Swiss Grisons. The product is available in three surface structures:
The surface ‘smooth’ is characterised by a smooth surface, which varies between polished and matt parts (lappato effect); the surface ‘rough’ is rough and matt and has a slight mica effect; the surface ‘struc’ is similar to this texture but much more structured.

Vals Smooth

Vals Rough

Vals Struc

Resolut

The series is defined by a characteristically vivid colour scheme with a slight metal reflection. The surface structure is uneven, rough and matt; it has a fossil natural stone character. The series is available in three colours: the colour ‘sand’ is beige-light brown; the colour ‘brown’ is light-/ dark brown; the colour ‘grey’ is dark grey-dark brown.

Resolut Sand

Resolut Brown

Resolut Grey

Fulda

The series is based on a very well-known, but no longer available natural stone from a quarry near Fulda in northern Hessen/Germany. The look is characterized by a lively combination of calcite, dolomite and quartz layers. The surface is matt and rough. The series is available in four colours: the colour “sand” is beige, the colour “grey” is grey, the colour “darkgrey” is dark grey and the colour “brown” is based on the dark brown shade of the original stone.

Fulda Sand

Fulda Brown

Fulda Grey

Fulda Dark Grey

Grace

The series is characterized by an elegant and natural appearance. The relatively even colouring combines harmoniously with sinuous veins. The surface is matt and rough and is oriented towards the character of sandstone. The series is available in three colours: the colour “sand” is beige; the colour “malt” is dove blue-grey; the colour “grey” is light grey.

Grace Sand

Grace Malt

Grace Grey