PRODUCT
glass mosaic
Delta Elements GLASS MOSAIC is made of frost-proof float glass, optionally superwhite glass, with colored enamel on the back, including a white overlay, not solid-colored. The glass mosaics are on sheets, secured by a transparent adhesive foil on the front, optional with a glued mesh on the reverse side. The surface is glossy or optionally frosted. The product can be supplied in various formats, thicknesses and colors/color mixtures and surface refinements; color gradients and image motifs are possible.
Areas of application
Exterior/facades
– As exterior wall and ceiling cladding on massive ground
– As cladding on exterior wall insulation systems (EWI systems)
– As cladding on suspended, rear-ventilated plaster support systems
Interior
– As wall and ceiling cladding
– As flooring in private residences with low traffic
– As swimming pool lining in private houses
Standard Formats
25 x 25 mm
50 x 50 mm
Special Formats
25 x 50 mm
25 x 75 mm
Material Thicknesses
4 mm
8 mm
Surfaces
glossy
frosty
PRODUCT FEATURES
- With general building approval for EWI systems (50x50 mm max.) and ventilated facade systems
- Quality glass with colored enamel on the back, including a white overlay, not solid-colored
- Crystalline look due to gloss and depth effect; surface optionally frosted
- Various formats, thicknesses and colors available
- Individual color mixtures/-gradients and image motifs are possible
- Fast processability of the sheets; transparent adhesive foil on the front
- Very low water absorption and wet stretching
- High resistance to stain and chemicals
- Shock and impact resistance also on EWI systems
- Good abrasion resistance and high breaking strength
- Easy removal of paint smears/graffiti
- Resistance to frost, de-icing salt, temperature changes and UV radiation
- Extremely low porosity with a low water absorption of <0.5%
- No staining, sanding or algae formation
- High color fastness/very low color variations
- A1 fire protection classification of the covering according to DIN 4108
- Low maintenance effort compared to plastered surfaces
- Can also be used as interior wall cladding
FACADE SYSTEMS
Delta Elements GLASS MOSAIC may be applied on different substrates. Here you can find constructional information and documents for the application of GLASS MOSAIC on EWI systems. We would be pleased to work with you on solutions for project-specific construction- and details-solutions.
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
Delta Elements GLASS MOSAIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.
1 Delta Elements GLASS MOSAIC
2 System-joint mortar, slurry method
3 System-adhesive mortar
4 System-equalizing mortar layer
5 System-basic plaster with textile
6 System-thermal insulation plate, doweled through the textile
7 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
Delta Elements GLASS MOSAIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.
1 Delta Elements GLASS MOSAIC
2 System-joint mortar, slurry method
3 System-adhesive mortar
4 System-equalizing mortar (possibly)
5 System-basic plaster with textile
6 System-priming coat
7 System-facade carrier plate
8 Rear ventilation/aluminium construction
9 System-thermal insulation plate, doweled
10 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
1 Delta Elements GLASS MOSAIC
2 Joint mortar, slurry method
3 Adhesive mortar
4 Equalizing mortar
5 Basic plaster with textile
6 Priming coat
7 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
- EWI SYSTEM
- rear-ventilated plaster support system
- MASSIV
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
Delta Elements GLASS MOSAIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.
1 Delta Elements GLASS MOSAIC
2 System-joint mortar, slurry method
3 System-adhesive mortar
4 System-equalizing mortar layer
5 System-basic plaster with textile
6 System-thermal insulation plate, doweled through the textile
7 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
Delta Elements GLASS MOSAIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.
1 Delta Elements GLASS MOSAIC
2 System-joint mortar, slurry method
3 System-adhesive mortar
4 System-equalizing mortar (possibly)
5 System-basic plaster with textile
6 System-priming coat
7 System-facade carrier plate
8 Rear ventilation/aluminium construction
9 System-thermal insulation plate, doweled
10 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.
1 Delta Elements GLASS MOSAIC
2 Joint mortar, slurry method
3 Adhesive mortar
4 Equalizing mortar
5 Basic plaster with textile
6 Priming coat
7 Sustainable massive ground
Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings
PROCESSING| STORAGE
GLASS MOSAIC has to be processed by the floating-method (mortar on one side) according to DIN EN 12004. Full-surface adhesion of the product is essential. The optimum processing temperature is between 5 and 30° C. The product has to be stored implicit dry, in the shade, dust- and frost-proof and has to be processed within 6 month after production date.
The detailed processing instructions can be found here:
To ensure the quality of execution we offer support on construction site in cooperation with our system partners.
Therefore we can provide you with advice for a successful completion of your work.