Delta Elements CERAMIC MOSAIC is made of frost-proof, colored glazed stoneware, not solid-colored. The mosaics are fixed on sheets, secured by a transparent adhesive foil on the front, optional with a glued mesh on the reverse side. The surface is silk matt as standard, optionally glossy. The product can be supplied in various formats and 50 natural colors; special productions are possible for large quantities.

Glazed stoneware (GL), group BIb, DIN EN 14411, frost-proof, glazed, HT finish, stress groups 1-4 (depending on color), slip resistance R9 (25×25/ 50×50), fire protection class B1

Areas of application

Exterior/facades
– As exterior wall and ceiling cladding on massive ground
– As cladding on exterior wall insulation systems (EWI systems)
– As cladding on suspended, rear-ventilated plaster support systems

Interior
– As wall and ceiling cladding
– As flooring in private and commercial areas with low traffic
– As swimming pool lining in private and commercial areas

Standard Formats

25 x 25 mm
50 x 50 mm
100 x 100 mm

Special Formats

on request

Material Thicknesses

6,5 mm

Surfaces

silk-matt
glossy (on request)

HAVE YOU BECOME CURIOUS?

Our project managers will be happy to advise you.

PRODUCT FEATURES

FACADE SYSTEMS

Delta Elements CERAMIC MOSAIC may be applied on different substrates. Here you can find constructional information and documents for the application of CERAMIC MOSAIC on EWI systems. We would be pleased to work with you on solutions for project-specific construction- and details-solutions.

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
System-joint mortar, slurry method
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
System-joint mortar, slurry method
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
Joint mortar, slurry method
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on exterior wall insulation systems (EWI system) which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
System-joint mortar, slurry method
System-adhesive mortar
System-equalizing mortar layer
System-basic plaster with textile
System-thermal insulation plate, doweled through the textile
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on suspended, rear-ventilated plaster support systems which are certified by construction authority. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
System-joint mortar, slurry method
System-adhesive mortar
System-equalizing mortar (possibly)
System-basic plaster with textile
System-priming coat
System-facade carrier plate
Rear ventilation/aluminium construction
System-thermal insulation plate, doweled
10  Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18516-1 Ventilated cladding facade systems
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

All specifications and drawings do not constitute any guarantee in regards to the recommendations provided. Delta Elements assumes no liability and refers to its general business terms and conditions. No rights of any kind can be derived from the contents of this information. The respective current version and the general business terms and conditions can be found at www.deltaelements.eu; printing errors reserved.

Delta Elements CERAMIC MOSAIC can be processed on various sustainable massive walls. Our processing instructions, the processing instructions of the facade system manufacturers and the below listed DIN norms and guidelines have to be observed. You will find our processing instructions at the download center. Further technical information is available on request.

Delta Elements CERAMIC MOSAIC
Joint mortar, slurry method
Adhesive mortar
Equalizing mortar
Basic plaster with textile
Priming coat
Sustainable massive ground

Standards and directives
DIN 18157 Installation of ceramic coverings using the glue-fixing method
DIN EN 12004 Mortar and adhesives for ceramic tiles and panels
DIN 18352 Tiling and paving
DIN 18515-1 Exterior wall cladding – tiles or panels applied with mortar
DIN 18540 Sealing exterior wall joints in building construction using joint sealing compound
DIN 18202 Dimensional tolerances for building construction
DIN EN 14411 Tolerances for ceramic tiles and panels
ZDB-leaflet: Expansion joints in tile and panel cladding and coverings

PROCESSING| STORAGE

CERAMIC MOSAIC has to be processed by the floating-method (mortar on one side) according to DIN EN 12004. Full-surface adhesion of the product is essential. The optimum processing temperature is between 5 and 30° C. The product has to be stored implicit dry, in the shade, dust- and frost-proof and has to be processed within 6 month after production date.

The detailed processing instructions can be found here: